1. Core Parameters
|
Parameter Category
|
Specific Parameters
|
|---|---|
|
Electrical Characteristics
|
Rated Voltage: 220V (supports wide voltage range); Rated Current: 40A; Frequency Range: 50-60Hz
|
|
Protection Characteristics
|
Supports differential protection (including motor/transformer differential, feeder differential), with second harmonic braking and ratio braking characteristics
|
|
Communication Interface
|
Supports RS-485 Modbus RTU and GOOSE optical fiber direct connection (point-to-point) or switch networking; Synchronous sampling error < 0.1°
|
|
Response Time
|
Section fault action time < 15 ms; CT line disconnection blocking time < 200 ms
|
|
Installation Method
|
DIN rail or panel mounting; Frame size: 160, mounting method: B3
|
|
Environmental Adaptability
|
Protection Class: IP55, suitable for harsh industrial environments; Supports multiple temperature grades and industrial-grade operating temperature ranges
|
______________________________________________________________________________________________
2. Product Features
- High-speed and Accurate Protection Logic: Advanced algorithms are adopted to effectively brake motor starting current and second harmonic, which can block the starting current at 15% fundamental current, quickly identify and isolate faults.
- Multiple Communication Capabilities: In addition to the traditional Modbus RTU protocol, it also supports precise synchronous communication based on IEEE 1588v2 PTP protocol, suitable for modern smart grid and industrial internet applications.
- Flexible Installation and Maintenance: Modular design supports quick DIN rail installation, easy replacement during maintenance, and reduces system downtime.
- Strong Compatibility: Specifically designed for GE Multilin series protection relays, it can be seamlessly integrated with other GE products, and is widely used in chemical, petroleum, electronics, aerospace and other industries.

______________________________________________________________________________________________
3. Structure and Composition
- Core Processing Unit (CPU): Responsible for executing protection logic algorithms, data calculation and signal processing.
- Input/Output Terminals: Including analog input (current, voltage), digital input (status) and relay output (trip signal).
- Communication Interface: Such as RS-485 interface and optical fiber interface, used for communication with upper computer or other protection equipment.
- Power Supply Module: Provides the DC power required by the module itself, usually with built-in power management function.
______________________________________________________________________________________________
4. Main Application Fields
- Motor Protection: Protects three-phase motors from faults such as phase-to-phase short circuit, ground short circuit, overload, phase loss and phase sequence error.
- Transformer Protection: Used to detect internal faults, load abnormalities and external short circuits of transformers.
- Power System Automation: As the core node of the distribution automation system, it participates in feeder differential protection and line fault location.
- Industrial Automation Control: In the automatic production line, it cooperates with PLC and SCADA systems to realize intelligent monitoring of equipment.
______________________________________________________________________________________________
5. Installation and Maintenance Guide
Installation Steps
- Confirm Power Supply: Check whether the on-site power supply voltage (usually 220V or 380V) is within the rated range of the equipment.
- Select Installation Method: Choose DIN rail installation or panel fixing according to the on-site space.
- Wiring: Strictly connect the power cord, input signal line (CT current transformer, PT voltage transformer) and output relay line according to the schematic diagram.
- Power-on Inspection: After turning on the power, check whether the equipment indicator lights are normal and confirm that the communication interface (such as RS-485) is connected correctly.
Maintenance Points
- Regularly Check Wiring: Especially the secondary side wiring of the CT current transformer, to avoid misoperation caused by loose wiring.
- Firmware Upgrade: Regularly check and upgrade the protection logic firmware through GE’s intelligent electrical software (such as Midas or Multilin system) to obtain the latest protection algorithms.
- Environmental Cleaning: Ensure that the module’s heat dissipation holes are unobstructed to prevent overheating caused by dust accumulation.
————————————————————————————————-
Main brand
ABB Allen-Bradley Alstom Bently Emerson Foxboro
GE MOOG Schneider Woodward HIMA Honeywel Triconex & more
Contact our professional team today for customized solutions to meet your electrical component needs.
📧 x13806028623@gmail.com / johnedward.zch@gmail.com
📞 +86 18250705533(Whatsapp)丨Sales Manager : Jinny/John




-480x480.jpg)

There are no reviews yet.